English
CE Source Four jr & CE Source Four jr Zoom • 7
HPL lamps
HPL lamps are tungsten halogen lamps.
Important:
Verify that the HPL lamp you use is suitable for the
voltage at your facility. 230V and 240V HPL lamps are available.
Operating HPL lamps above their rated voltage reduces lamp life
and can cause premature lamp failure.
Installing the HPL lamp
Important:
The lamp must be installed before you use the
luminaire.
Caution!
Always replace the lamp if it becomes damaged or
thermally deformed.
1.
Disconnect the unit from power before installing and replacing the
lamp.
2.
Loosen the knurled bolt on the back of the lamp housing and pull
the housing straight out.
3.
Remove the HPL lamp from its box, holding it by the base.
Note:
To avoid premature lamp failure, do not touch the lamp glass.
If you do touch the lamp, clean it carefully with rubbing
alcohol and a clean, lint-free cloth before operation.
4.
Line up the flat sides of the lamp base with the retention brackets
on either side of the socket. See
Figure 3
.
5.
Push down on the lamp base until the lamp seats firmly. (The top of
the lamp base will be even with the top edges of the retention
brackets when it is properly installed.)
WARNING!
Do not use lamps other than the HPL in CE Source
Four jr/Zoom luminaires.
Use of lamps other than HPL will void
CE safety conformity and warranty.
Lamp code Watts Volts Color temp Ave rated life
HPL 575/230
575 230 3,200ºK 400 hour
HPL 575/240 575 240 3,200ºK 400 hour
HPL 375/115 375 115 3,250ºK 300 hour
HPL 375/115X 375 115 3,050ºK 1,000 hour
HPL 550/77 550 77 3,250ºK 300 hour
HPL 550/77X 550 77 3,050ºK 2,000 hour
HPL 575/115 575 115 3,250ºK 300 hour
HPL 575/115X 575 115 3,050ºK 2,000 hour
HPL 575/120 575 120 3,250ºK 300 hour
WARNING!
Let lamp cool before changing.