Quick Start 7
Quick Start
This section details the steps for a quick fixture setup.For more comprehensive information,
see Operation, page 45.
Install
Step 1: Hang or mount the fixture using the provided hardware and approved hardware
accessories.
Step 2: Attach an approved safety cable when applicable.
Step 3: Insert secondary lenses with the smooth side out, if desired.
Step 4: Insert additional accessories (top hat, egg crate, etc.) into the holder, if desired.
Connect (D40, D40XT, D60)
Step 1: Attach the power cable to the Power In connector.
Step 2: Attach 5-pin XLR cable to the DMX In connector (if using external control).
Step 3: Plug the power cable into AC power (100 to 240VAC, 50/60 Hz) on a
non-dimming circuit.
Step 4: Plug the XLR cable (if using) into the DMX source or data daisy-chain.
Step 5: Link additional fixtures via the Power Out and DMX Out connectors using the
following guidelines.
• No more than nine total D40 or D40XT fixtures on Power Thru.
• Up to 32 device loads on the DMX daisy-chain.
Connect (D22 Portable)
Step 1: Attach 5-pin XLR cable to the DMX In connector (if using external control).
Step 2: Plug the power cable into AC power (100 to 240VAC, 50/60 Hz) on a
non-dimming circuit.
Step 3: Plug the XLR cable (if using) into the DMX source or data daisy-chain.
WARNING:
• Do not link more than nine fixtures when using Power Thru (non-dimming,
100 to 240 VAC, 50/60 Hz). Power Thru is not available on all Desire
Series fixtures.
• Up to 32 devices can be daisy-chained together per data run.