The Source Four Revolution high performance automated ellipsoidal spotlight is intended for professional
use only. Read entire User Manual before using equipment.
Seitenansicht 0
1 2 3 4 5 6 ... 51 52

Inhaltsverzeichnis

Seite 1 - User Manual

With Wybron InsideUser ManualRev B November 2007Copyright © 2007. Electronic Theatre Controls, Inc. All rights reserved. Product information and speci

Seite 2

6 Source Four Revolution User ManualDimensions and Hanging Clearances344mm(13.5")317mm(12.5")454mm(17.9")394mm(15.5")400mm(15.7&qu

Seite 3 - Table of Contents

Overview 7Safety CableThe safety cable (or other approved safety device) should be secured to one of the handles on the upper enclosure, wrapped aroun

Seite 4 - Specifications

8 Source Four Revolution User ManualConnections and AddressingConnect AC input power and DMX data cables to the appropriate ports as shown below. Conn

Seite 5 - Overview

Overview 9Power-up Procedure and CalibrationMove the power switch/breaker to the “on” position to apply power to the fixture. CAUTION:The Source Four

Seite 6 - Document Conventions

10 Source Four Revolution User ManualControlThe Source Four Revolution fixture can take as few as 14 and up to 31 DMX channels to operate. The table b

Seite 7

Overview 11Control Values Standard 12-Color Gel String.16-Color Gel StringFrameGel Numberaa) R = Roscolux and Rosco Supergel numbers.ColorPercent Star

Seite 8 - Installation

12 Source Four Revolution User Manual20-Color Gel StringFramePercent StartPercent EndPercent Center FrameDMX Start DMX EndDMX Center Frame103006123856

Seite 9 - Installation procedures

Overview 1324-Color Gel StringReset ChannelTo use the Reset Channel (Channel 12), set the channel to one of the levels shown below for three seconds,

Seite 10

14 Source Four Revolution User ManualTiming ChannelsThree timing channels are provided: Focus Timing (Channel 9), Color Timing (Channel 10), and Beam

Seite 11 - Fixture Weight

Configuration 15ConfigurationWith Source Four Revolution, you decide how to configure your light. The standard base unit provides pan, tilt, beam-edge

Seite 12

ETC, Source Four, Revolution, and QXL are registered trademarks of Electronic Theatre Controls, Inc. in the United States and other countries. Other p

Seite 13 - Power-down Procedure

16 Source Four Revolution User ManualRemoving and Replacing ModulesEach module is secured with two thumbscrews. See the diagram below for bay designat

Seite 14

Configuration 17Blank Module (BM)The Blank Module is used to fill an empty module bay, and can be used to hold a static M-Size metal gobo, if needed.F

Seite 15 - Control Values

18 Source Four Revolution User ManualIris Module (IM)The Iris Module contains an 18-leaf iris and can be placed in either module bay.

Seite 16 - 20-Color Gel String

Configuration 19Shutter Module (SM)The Shutter Module contains a four-blade shutter mechanism. Each shutter can be rotated +/– 45° (total range of mot

Seite 17 - Reset Channel

20 Source Four Revolution User ManualStatic Wheel Module (SWM)The Static Wheel Module contains a wheel with three positions for static M-size steel or

Seite 18 - Timing Channels

Configuration 21Rotating Wheel Module (RWM)The Rotating Wheel Module contains a wheel with three rotating/indexing positions for static M-size steel o

Seite 19 - Configuration

22 Source Four Revolution User ManualControlling the Rotating Wheel ModuleThe Rotating Wheel Module uses two 8-bit channels to select the frame and de

Seite 20 - CAUTION:

Configuration 23Replacing Gobos and FiltersThe Static Wheel Module and the Rotating Wheel Module both use the same gobo/filter retention method. In ea

Seite 21 - Blank Module (BM)

24 Source Four Revolution User ManualStep 6: Insert the spring into the frame. Ensure that the gobo/filter is held securely in place and that the spri

Seite 22 - Iris Module (IM)

Routine Maintenance 25Routine MaintenanceTo ensure optimum performance of your Source Four Revolution fixture, you should perform the following inspec

Seite 23 - Shutter Module (SM)

Table of Contents iTable of ContentsSpecifications . . . . . . . . . . . . . . . . . . . . iiOverview . . . . . . . . . . . . . . . . . . . . . . . .1

Seite 24 - Static Wheel Module (SWM)

26 Source Four Revolution User ManualProceduresScroller Cartridges and Beam Containment DevicesThe Source Four Revolution fixture is provided with a r

Seite 25 - Rotating Wheel Module (RWM)

Routine Maintenance 27Step 4: While pulling the latch on the top of the cartridge forward, press the cartridge into place. Ensure that the gel is posi

Seite 26

28 Source Four Revolution User ManualGel StringsYou can change the gel string in your fixture. Replacement strings must have a minimum of 4 frames or

Seite 27 - Replacing Gobos and Filters

Routine Maintenance 29Removing the gel string:Step 1: Using your finger, turn the trailer roller drive wheel (hook and loop pad) at the bottom of the

Seite 28

30 Source Four Revolution User ManualStep 7: Refer to the gel string tension table below and turn the leader roller toward the trailer roller (clockwi

Seite 29 - Routine Maintenance

Routine Maintenance 31Changing the gel in the internal media frame:Step 1: Power-down the fixture. See Power-down Procedure, page 9.Step 2: Lock the f

Seite 30 - Procedures

32 Source Four Revolution User ManualStep 7: Remove the old media and replace the media in each frame. Trim the media to the shape of the frame. Trim

Seite 31

Routine Maintenance 33Note:If the spring clip does not allow enough movement, move the spring to the next notch in the clip.Step 7: When the pawl oper

Seite 32 - Gel Strings

34 Source Four Revolution User ManualChanging and Adjusting the LampThe QXL™ 750/77 lamp is remarkably easy to replace. No tools are required and the

Seite 33

Routine Maintenance 35Adjusting the lamp:Step 1: Apply power to the fixture and allow it to complete its calibration.Step 2: Bring intensity to full a

Seite 34 - Internal Media Frame (IMF)

ii Source Four Revolution User ManualSpecificationsPhysical• Die cast aluminum construction • High strength yoke for hanging in any orientation• Rugge

Seite 35 - Routine Maintenance 31

36 Source Four Revolution User ManualAdjusting Belt TensionsOver time and with repeated use, belts may loosen. Belts that are too loose may cause the

Seite 36 - Adjusting the IMF

Routine Maintenance 37Adjusting pan belt tension:Step 1: Power-down the fixture (see Power-down Procedure, page 9) and disconnect any power and data c

Seite 37 - Left IMF door shown

38 Source Four Revolution User ManualAdjusting the Scroller, Front Lens, and Rear Lens BeltsTo access the three belts inside the head, you will need t

Seite 38 - WARNING:

Routine Maintenance 39Adjusting the scroller drive belt tension:Step 1: See General belt adjustment instructions:, page 38.Step 2: Remove the scroller

Seite 39 - Routine Maintenance 35

40 Source Four Revolution User ManualAdjusting the front lens belt:Step 1: See General belt adjustment instructions:, page 38.Step 2: Using both hands

Seite 40 - Adjusting Belt Tensions

Routine Maintenance 41Adjusting rear lens belt:Step 1: See General belt adjustment instructions:, page 38.Step 2: Using both hands, gently move the IM

Seite 41

42 Source Four Revolution User ManualTroubleshootingLED IndicatorsThe easiest way to find out the status of your Source Four Revolution fixture is to

Seite 42

Routine Maintenance 43Internal Test SoftwareThe following diagnostic tests are available using the thumbwheels on your Source Four Revolution fixture.

Seite 43 - Belt Tension

44 Source Four Revolution User Manual

Seite 44

Routine Maintenance 45

Seite 45 - Routine Maintenance 41

Overview 1OverviewCongratulations on your purchase of the Source Four® Revolution™ fixture. Source Four Revolution has been engineered for maximum per

Seite 46 - Troubleshooting

46 Source Four Revolution User Manual

Seite 47 - Internal Test Software

Photometric DataMinimum SpreadMedian SpreadMaximum Spread37.2ft 44.7ft 52.1ft 59.6ft11.3m 13.6m 15.9m 18.2m10ft 12ft 14ft 16ft3.0m 3.7m 4.3m 4.9mFC 27

Seite 48

Corporate Headquarters  3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel +608 831 4116  Fax +608 836 1736London,

Seite 49 - Routine Maintenance 45

2 Source Four Revolution User ManualDocument ConventionsThroughout this manual, the following are used to alert you to notes and safety notices.Note:N

Seite 50

Overview 3SafetyThe Source Four Revolution high performance automated ellipsoidal spotlight is intended for professional use only. Read entire User Ma

Seite 51 - Photometric Data

4 Source Four Revolution User ManualInstallationPower and Data cabling requirementsThe Source Four Revolution fixture operates on AC power, 100-240VAC

Seite 52

Overview 5Installation proceduresInstalling hanging hardwareThe Source Four Revolution fixture’s upper enclosure provides six bolt holes for installat